Nova V4
One cabinet. Twelve connectors.

An air-cooled central power cabinet in 480 and 720 kW ratings that pools power across up to 12 dispenser connectors, with 97% peak efficiency.
Key facts
- Maximum output
- 720 kW
- Dispenser connectors per cabinet
- 12
- Peak efficiency
- 97 %
- Maximum output current, 720 kW
- 2400 A
Highlights
Smart power pool
Power is shared dynamically across every connected dispenser.
Up to 12 outputs
One cabinet feeds up to 12 dispenser connectors from a small footprint.
97% peak efficiency
High output current, up to 720 kW in total.
Two ratings
480 kW with 1600 A or 720 kW with 2400 A maximum output current.
MEA listed
The 720 kW model is on the MEA list as well as NBTC, PTEC and PEA.

Power flows where it's needed.
- Up to 12 dispenser connectors
- 480 or 720 kW ratings
- 97% peak efficiency
- Up to 2400 A output current
- MEA listed at 720 kW
Technical specifications
| Version | 480 kW | 720 kW | |
|---|---|---|---|
| Input | AC input voltage | 400 V AC ±15%, 3-phase, 50/60 Hz, 2 × (L1+L2+L3+N+PE) | |
| AC input current | 737 A | 1100 A | |
| Power factor | ≥0.99 at full load | ||
| Peak efficiency | 97% | ||
| Earthing system | TN-S, TN-C-S, TT | ||
| Output | Output power | 480 kW | 720 kW |
| Output voltage | 150–1000 V DC | ||
| Output current | 1600 A max. | 2400 A max. | |
| Overvoltage category | CAT III | ||
| Max. dispenser connectors | 12 per cabinet | ||
| Interface and connectivity | Button | Emergency stop | |
| Connectivity | 4G, Wi-Fi, Ethernet | ||
| Backend protocol | OCPP 1.6J | ||
| Environment | Operating / storage temperature | −30 to +50 °C / −40 to +70 °C | |
| Humidity / altitude | 5–95% non-condensing / ≤2000 m | ||
| Corrosion class | C3-M | ||
| IP / IK rating | IP55 / IK10 | ||
| Cooling | Forced air | ||
| Mechanical | Dimensions (W × H × D) | 1503 × 2149.5 × 1220 mm | |
| Weight | Cabinet approx. 800 kg; approx. 15 kg per power module | Cabinet approx. 880 kg; approx. 17 kg per power module | |
| Installation | Ground mounting | ||
| Compliance | Standards | IEC 61851-1, IEC 61851-21-2, IEC 61851-23, LVD 2014/35/EU, RED 2014/53/EU | |
| Certification | CE-RED, CB, NBTC, PTEC, PEA list | CE-RED, CB, NBTC, PTEC, PEA list, MEA list | |
| Version | 480 kW |
|---|---|
| Input | |
| AC input voltage | 400 V AC ±15%, 3-phase, 50/60 Hz, 2 × (L1+L2+L3+N+PE) |
| AC input current | 737 A |
| Power factor | ≥0.99 at full load |
| Peak efficiency | 97% |
| Earthing system | TN-S, TN-C-S, TT |
| Output | |
| Output power | 480 kW |
| Output voltage | 150–1000 V DC |
| Output current | 1600 A max. |
| Overvoltage category | CAT III |
| Max. dispenser connectors | 12 per cabinet |
| Interface and connectivity | |
| Button | Emergency stop |
| Connectivity | 4G, Wi-Fi, Ethernet |
| Backend protocol | OCPP 1.6J |
| Environment | |
| Operating / storage temperature | −30 to +50 °C / −40 to +70 °C |
| Humidity / altitude | 5–95% non-condensing / ≤2000 m |
| Corrosion class | C3-M |
| IP / IK rating | IP55 / IK10 |
| Cooling | Forced air |
| Mechanical | |
| Dimensions (W × H × D) | 1503 × 2149.5 × 1220 mm |
| Weight | Cabinet approx. 800 kg; approx. 15 kg per power module |
| Installation | Ground mounting |
| Compliance | |
| Standards | IEC 61851-1, IEC 61851-21-2, IEC 61851-23, LVD 2014/35/EU, RED 2014/53/EU |
| Certification | CE-RED, CB, NBTC, PTEC, PEA list |
Values from the StarCharge Thailand datasheets, September 2026. Figures on the StarCharge website may differ.
Approvals
Certified for the Thai market on top of CE-RED and CB.
- CE-RED
- CB
- NBTC
- PTEC
- PEA list
- MEA list (720 kW)
Long-run
support.
A charger is a 10-year decision. Terros installs, maintains and supports every model in Thailand.