Nereus 720 LC
Liquid-cooled. Built for decades.

A liquid-cooled power cabinet built from 40 kW modules, scaling to 720 kW across up to 18 connectors, with redundant cooling and a 10-year maintenance-free rating.
Key facts
- Maximum output
- 720 kW
- Dispenser connectors per cabinet
- 18
- Module efficiency
- 97 %
- Maintenance-free lifespan
- 10 years
Highlights
DPA power pool
An optimisation algorithm holds module efficiency at 97%.
40 kW increments
Power is allocated in 40 kW steps, raising utilisation by 28%.
10 years, maintenance-free
Liquid and electrical isolation for extreme environments.
Redundant cooling
Two coolant pumps and three fans keep the cabinet running.
Scales to 720 kW
Up to 18 dispenser connectors per cabinet.
Hot-swappable modules
Quick fluid connectors on every 40 kW power module.

Ten years, maintenance-free.
- Scales to 720 kW
- Up to 18 connectors
- 97% module efficiency
- Hot-swappable 40 kW modules
- Redundant pumps and fans
Technical specifications
| Version | 720 kW | |
|---|---|---|
| Input | AC input voltage | 400 V AC ±10%, 3-phase, 50/60 Hz, 2 × (L1+L2+L3+N+PE) |
| AC input current | 1088 A | |
| Power factor | ≥0.99 at full load | |
| Peak efficiency | 96.5% (module 97%) | |
| Earthing system | TN-S, TN-C-S, TT | |
| Output | Output power | 720 kW |
| Output voltage | 150–1000 V DC | |
| Output current | 2400 A max. | |
| Overvoltage category | CAT III | |
| Max. dispenser connectors | 18 per cabinet | |
| Interface and connectivity | Button / status | Emergency stop button; LED indicator |
| Connectivity | 4G, Wi-Fi, Ethernet | |
| Backend protocol | OCPP 1.6J / OCPP 2.0.1 | |
| Environment | Operating / storage temperature | −30 to +50 °C / −40 to +70 °C |
| Humidity / altitude | 5–95% non-condensing / ≤2000 m | |
| Corrosion class | C3-M | |
| IP / IK rating | IP55 / IK10 | |
| Cooling | Liquid cooling (ethylene glycol) | |
| Liquid cooling unit | Power module capacity | 40 kW |
| Fluid quick connector | Hot-swappable | |
| Thermal load per module | Approx. 1.2 kW per power module at 400 V AC input, 800 V DC output | |
| Coolant flow rate | ≥110 L/min per cabinet (18 power modules) | |
| Redundancy | Two coolant pumps and three fans | |
| Pump | Centrifugal; rated pressure 2 bar max. | |
| Mechanical | Dimensions (W × H × D) | 2000 × 2100 × 950 mm |
| Weight | Approx. 1800 kg | |
| Installation | Ground mounting | |
| Compliance | Standards | IEC 61851-1, IEC 61851-21-2, IEC 61851-23, LVD 2014/35/EU, RED 2014/53/EU |
| Certification | CE-RED, CB, NBTC, PTEC, PEA list |
| Version | 720 kW |
|---|---|
| Input | |
| AC input voltage | 400 V AC ±10%, 3-phase, 50/60 Hz, 2 × (L1+L2+L3+N+PE) |
| AC input current | 1088 A |
| Power factor | ≥0.99 at full load |
| Peak efficiency | 96.5% (module 97%) |
| Earthing system | TN-S, TN-C-S, TT |
| Output | |
| Output power | 720 kW |
| Output voltage | 150–1000 V DC |
| Output current | 2400 A max. |
| Overvoltage category | CAT III |
| Max. dispenser connectors | 18 per cabinet |
| Interface and connectivity | |
| Button / status | Emergency stop button; LED indicator |
| Connectivity | 4G, Wi-Fi, Ethernet |
| Backend protocol | OCPP 1.6J / OCPP 2.0.1 |
| Environment | |
| Operating / storage temperature | −30 to +50 °C / −40 to +70 °C |
| Humidity / altitude | 5–95% non-condensing / ≤2000 m |
| Corrosion class | C3-M |
| IP / IK rating | IP55 / IK10 |
| Cooling | Liquid cooling (ethylene glycol) |
| Liquid cooling unit | |
| Power module capacity | 40 kW |
| Fluid quick connector | Hot-swappable |
| Thermal load per module | Approx. 1.2 kW per power module at 400 V AC input, 800 V DC output |
| Coolant flow rate | ≥110 L/min per cabinet (18 power modules) |
| Redundancy | Two coolant pumps and three fans |
| Pump | Centrifugal; rated pressure 2 bar max. |
| Mechanical | |
| Dimensions (W × H × D) | 2000 × 2100 × 950 mm |
| Weight | Approx. 1800 kg |
| Installation | Ground mounting |
| Compliance | |
| Standards | IEC 61851-1, IEC 61851-21-2, IEC 61851-23, LVD 2014/35/EU, RED 2014/53/EU |
| Certification | CE-RED, CB, NBTC, PTEC, PEA list |
Values from the StarCharge Thailand datasheets, September 2026. Figures on the StarCharge website may differ.
Approvals
Certified for the Thai market on top of CE-RED and CB.
- CE-RED
- CB
- NBTC
- PTEC
- PEA list
Long-run
support.
A charger is a 10-year decision. Terros installs, maintains and supports every model in Thailand.