A liquid-cooled power cabinet built from 40 kW modules, scaling to 720 kW across up to 18 connectors, with redundant cooling and a 10-year maintenance-free rating.

Key facts

Maximum output
720 kW
Dispenser connectors per cabinet
18
Module efficiency
97 %
Maintenance-free lifespan
10 years

Highlights

  • DPA power pool

    An optimisation algorithm holds module efficiency at 97%.

  • 40 kW increments

    Power is allocated in 40 kW steps, raising utilisation by 28%.

  • 10 years, maintenance-free

    Liquid and electrical isolation for extreme environments.

  • Redundant cooling

    Two coolant pumps and three fans keep the cabinet running.

  • Scales to 720 kW

    Up to 18 dispenser connectors per cabinet.

  • Hot-swappable modules

    Quick fluid connectors on every 40 kW power module.

Nereus 720 LC EV charger

Ten years, maintenance-free.

  • Scales to 720 kW
  • Up to 18 connectors
  • 97% module efficiency
  • Hot-swappable 40 kW modules
  • Redundant pumps and fans

Technical specifications

Version720 kW
InputAC input voltage400 V AC ±10%, 3-phase, 50/60 Hz, 2 × (L1+L2+L3+N+PE)
AC input current1088 A
Power factor≥0.99 at full load
Peak efficiency96.5% (module 97%)
Earthing systemTN-S, TN-C-S, TT
OutputOutput power720 kW
Output voltage150–1000 V DC
Output current2400 A max.
Overvoltage categoryCAT III
Max. dispenser connectors18 per cabinet
Interface and connectivityButton / statusEmergency stop button; LED indicator
Connectivity4G, Wi-Fi, Ethernet
Backend protocolOCPP 1.6J / OCPP 2.0.1
EnvironmentOperating / storage temperature−30 to +50 °C / −40 to +70 °C
Humidity / altitude5–95% non-condensing / ≤2000 m
Corrosion classC3-M
IP / IK ratingIP55 / IK10
CoolingLiquid cooling (ethylene glycol)
Liquid cooling unitPower module capacity40 kW
Fluid quick connectorHot-swappable
Thermal load per moduleApprox. 1.2 kW per power module at 400 V AC input, 800 V DC output
Coolant flow rate≥110 L/min per cabinet (18 power modules)
RedundancyTwo coolant pumps and three fans
PumpCentrifugal; rated pressure 2 bar max.
MechanicalDimensions (W × H × D)2000 × 2100 × 950 mm
WeightApprox. 1800 kg
InstallationGround mounting
ComplianceStandardsIEC 61851-1, IEC 61851-21-2, IEC 61851-23, LVD 2014/35/EU, RED 2014/53/EU
CertificationCE-RED, CB, NBTC, PTEC, PEA list
Version720 kW
Input
AC input voltage400 V AC ±10%, 3-phase, 50/60 Hz, 2 × (L1+L2+L3+N+PE)
AC input current1088 A
Power factor≥0.99 at full load
Peak efficiency96.5% (module 97%)
Earthing systemTN-S, TN-C-S, TT
Output
Output power720 kW
Output voltage150–1000 V DC
Output current2400 A max.
Overvoltage categoryCAT III
Max. dispenser connectors18 per cabinet
Interface and connectivity
Button / statusEmergency stop button; LED indicator
Connectivity4G, Wi-Fi, Ethernet
Backend protocolOCPP 1.6J / OCPP 2.0.1
Environment
Operating / storage temperature−30 to +50 °C / −40 to +70 °C
Humidity / altitude5–95% non-condensing / ≤2000 m
Corrosion classC3-M
IP / IK ratingIP55 / IK10
CoolingLiquid cooling (ethylene glycol)
Liquid cooling unit
Power module capacity40 kW
Fluid quick connectorHot-swappable
Thermal load per moduleApprox. 1.2 kW per power module at 400 V AC input, 800 V DC output
Coolant flow rate≥110 L/min per cabinet (18 power modules)
RedundancyTwo coolant pumps and three fans
PumpCentrifugal; rated pressure 2 bar max.
Mechanical
Dimensions (W × H × D)2000 × 2100 × 950 mm
WeightApprox. 1800 kg
InstallationGround mounting
Compliance
StandardsIEC 61851-1, IEC 61851-21-2, IEC 61851-23, LVD 2014/35/EU, RED 2014/53/EU
CertificationCE-RED, CB, NBTC, PTEC, PEA list

Values from the StarCharge Thailand datasheets, September 2026. Figures on the StarCharge website may differ.

Approvals

Certified for the Thai market on top of CE-RED and CB.

  • CE-RED
  • CB
  • NBTC
  • PTEC
  • PEA list

Long-run An aerial view of a road through forested hills at dawn support.

A charger is a 10-year decision. Terros installs, maintains and supports every model in Thailand.